manufacturer
in measuring
Model 6500 Calibrator
voltage
current
resistance
J K L T U E N R S B T/C
Pt100 Ni100 RTD
Input and output range
| Type | Range |
Input resolution | Input Accuracy* | Output resolution | Output Accuracy* |
| mV-V | ± 21.000 mV ± 210.00 mV ± 2.1000 V |
0.001 mV 0.01 mV 0.1 mV |
± 0.05% ± 5c.** ± 0.03% ± 3c.** ± 0.03% ± 3c.** |
0.001 mV 0.01 mV 0.1 mV |
± 0.05% ± 5c.** ± 0.03% ± 3c.** ± 0.03% ± 2c.** |
| V Input V Out |
± 21.000 V ± 10.500 V |
1 mV - |
± 0.03% ± 3c.** - |
- 1 mV |
- ± 0.03% ± 2c.** |
| mA IN mA OUT |
± 21.000 mA 0 to 21.000 mA |
0.001 mA - |
± 0.03% ± 3c.** - |
0.001 mA | ± 0.03% ± 3c.** |
| W | 0 to 400 W 0 to 300 W |
0.1 W 1 W |
± 0.03% ± 3c.** ± 0.03% ± 3c.** |
0.1 W 1 W |
± 0.03% ± 2c.** ± 0.03% ± 2c.** |
| J, L | -200 to -100°C -100 to +1000°C -328 to +2192°C |
0.2°C 0.1°C 1 °F |
±0.5°C ±0.6°C ± 1 °F |
0.2 °C 0.1 °C 1 °F |
±0.5 °C ±0.6 °C ± 1 °F |
| K | -250 to -150°C -150 to +1350°C -364 to +1832°F |
0.5 °C 0.2 °C 1 °F |
±1°C ±0.7°C ± 2 °F |
0.5 °C 0.2 °C 1 °F |
± 1 °C ± 0.7 °C ±2 °F |
| T, U | -250 to -170°C -170 to 0°C 0 to 400°C -418 to -274°F -274 to +752°F |
0.5 °C 0.2 °C 0.1 °C 1 °F 0.5 °F |
± 1°C ±0.5°C ±0.4°C ±1°F ±1°F |
0.5 °C 0.2 °C 0.1 °C 1 °F 0.5 °F |
± 1°C ±0.5°C ±0.4°C ±1°F ±1°F |
| E | -250 to -130°C -130 to +1000°C -418 to -202°F -202 to +1832°F |
0.2 °C 0.1 °C 0.5 °F 0.5 °F |
± 1°C ±0.5°C ± 2°F ±1°F |
0.2 °C 0.1 °C 0.5 °F 0.5 °F |
± 1°C ±0.5°C ± 2°F ±1°F |
| N | -250 to +1300°C -418 to +2372°F |
0.5°C 1 °F |
± 1°C ± 2°F |
0.5°C 1 °F |
± 1°C ± 2°F |
| R | -50 to +1750°C -58 to +3182°F |
0.5°C 1 °F |
± 1°C ± 2°F |
0.5°C 1 °F |
± 1°C ± 2°F |
| S | -50 to +1750°C -58 to +3182°F |
0.5°C 1 °F |
± 1°C ± 2°F |
0.5°C 1 °F |
± 1°C ± 2°F |
| B | -10*** to +1820°C +14*** to +3308°F |
1 °C 2 °F |
± 2 °C ± 3 °F |
1 °C 2 °F |
± 2 °C ± 3 °F |
| Pt100 RTD | -200 to 800°C +800 to +850°C -328 to +1472 °F +1472 to 1562 °F |
0.1 °C 0.1 °C 0.2 °F 0.2 °F |
±0.2°C ±0.5°C ±0.5°F ±1°F |
0.1 °C 0.1 °C 0.2 °F 0.2 °F |
±0.2°C ±0.5°C ±0.5°F ±1°F |
| Ni100 RTD | -60 to +180°C -76 to +356°F |
0.1 °C 0.2 °F |
±0.2°C ±0.5°F |
0.1 °C 0.2 °F |
±0.2°C ±0.5°F |
* @ operating temperature of 15°C to 35°C (59°F to 95°F) and 30 days
calibration cycle, including conformity error.
** accuracy in % of reading/setting ± n counts.
*** on reading limited from +200°C/+392°F.
Common specifications
Input/Output isolation 500 V DC or AC peak maximum
Display 2 rows of 20 characters backlight LCD dot matrix
Reading rate Low 1.25 readings / sec
Normal 2.5 readings / sec
Fast 5 readings / sec
Connectors two groups of front termination posts
RS-232 interface D9 rear connector
AC power supply rear connector
Temperature stability ±15 ppM full scale + ±0.3 µV/°C typical
Warm-up time 1 min operating 5 min for rated accuracy
C J compensation manual adjustable from -50°C to +100°C
internal automatic from -10°C to +55°C
C J compensation drift ±0.02 °C/°C
C J compensation error ±0.3 °C
Operating temp. range -10 °C to 55 °C
Storage temp. range -40 °C to 60 °C
Power supply AC line, Ni-Mh rechargeable battery or Alkaline 4x type AA
Line operation 85 to 264 V AC 47 to 70 Hz
Line insulation 2500 V AC
Power consumption 8 VA (exhausted batteries)
Battery recharging time 2 hours for full charge
Battery operation time 8 hours (all functions) 5 hours (mA & ext. supply)
Battery protection Warning at battery run-down, automatic switching off before battery discharge
Case Injection moulded ABS
Dimensions 260 x 110 x 250 mm (400 x 200 x 400 packed)
Weights net 1.7 Kg gross 2.6 Kg
Input specifications
Input impedance 1000 MOhm (mV, T/C and 2V range)
1 MOhm (20 V range)
CMRR > 140 dB @ AC operation
NMRR > 70 dB @ 50 or 60 Hz
Common mode voltage 500 V DC or peak AC maximum
Input protection 500 V DC or peak AC maximum (mV, V, T/C input)
Response time 1 second maximum (to rated accuracy)
Rtd/Ohm excitation: 0.5 mA
Rtd/Ohm configuration: 2 or 3 wire
Shunt resistance (mA) 10 Ohm
Overload protection 1.6A/250V fuse (current ranges)
Output specifications
Output current 0 to 10 mA at rated accuracy (voltage and T/C ranges)
short-circuit protected
Output compliance up to 20V as generator (current & transmitter simulation)
up to 60V as controlled load
Response time 0.5 sec. max. (to 100% step change)
Rtd/Ohm exc.current: from 0.1 to 3 mA
Input and output auxiliary supply specifications Output voltage 24 V DC ±3% stabilized Output current 0 to 25 mA Output protection electronically protected against short-circuit
RS-232 serial interface
Baud rate from 1200 to 9600
Isolation 500 V DC or peak AC maximum
The electrical specifications given apply for an operating temperature